MNMR Center

Spectrometer Information

(click each tab to see its information)

  • 9001
  • 8501
  • 7002
  • 7001
  • 6002
  • 6001
  • 700SS
  • 600SS

Bruker 900 MHz Spectrometer

Description:

It has two probes of 1H sensitivity 11,000:1. It is proper to collect data for NMR study of proteins, nucleic acids, and small molecules for high sensitivity.

 

CryoProbe 5mm TCI probe of Z-Gradient:

1H S/N of sample 2mM Sucrose - 1,650:1
1H S/N of sample 0.1% EB - 11,000:1
13C S/N of sample ASTM - 2,100:1
VT - 0°C to 80°C

 

Room temp. 5mm TXI probe of Z-Gradient:

1H S/N of sample 2mM Sucrose - 570:1
1H S/N of sample 0.1% EB - 3,000:1
13C S/N of sample ASTM - 380:1
VT - -150°C to 150°C

9001 spectrometer

Bruker 850 MHz Spectrometer

Description:

It has two probes of 1H sensitivity 10,000:1. It is proper to collect data for NMR study of proteins, nucleic acids, and small molecules for high sensitivity.

 

CryoProbe 5mm TCI probe of Z-Gradient:

1H S/N of sample 2mM Sucrose - 1,600:1
1H S/N of sample 0.1% EB - 10,000:1
13C S/N of sample ASTM - 1,800:1
VT - 0°C to 80°C

 

Room temp. 5mm TXI probe of Z-Gradient:

1H S/N of sample Sucrose - 570:1
1H S/N of sample 0.1% EB - 2,500:1
VT - -150°C to 150°C

8501 spectrometer

Bruker 700 MHz Spectrometer

Description:

It has three probes. It is proper to collect data for study of metabonomics (sample volume as little as 30 micro liters), tissue and solid state sample.

 

CryoProbe 1.7mm TCI probe of Z-Gradient:

1H S/N of sample 2mM Sucrose - 380:1
1H S/N of sample 0.1% EB- 1,600:1
13C S/N of sample ASTM - 100:1
VT - 0°C to 80°C

 

4mm HRMAS probe of Z-Gradient:

MAS speed limit - 15 kHz; VT - -80°C to 80°C

 

3.2mm ssMAS probe of Z-Gradient:

MAS speed limit - 24 kHz; VT - -80°C to 80°C

7002 spectrometer

Bruker 700 MHz Spectrometer

Description:

It has two probes of 1H sensitivity 5,300:1. It is proper to collect data for NMR study of proteins, nucleic acids, and small molecules for high sensitivity.

 

CryoProbe 5mm TXI probe of Z-Gradient:

1H S/N of sample 2mM Sucrose - 800:1
1H S/N of sample 0.1% EB - 5,300:1
13C S/N of sample ASTM - 380:1
VT - 0°C to 80°C

 

Room temp. 5mm TXI probe of Z-Gradient:

1H S/N of sample 0.1% EB - 1,700:1
VT - -150°C to 150°C

 

7001 spectrometer

Agilent/Varian 600 MHz Spectrometer

Description:

It has two probes. It is proper to collect data for study of metabolomics and small molecules.

 

Room temp. 5mm HCN probe of Z-Gradient:

1H S/N of sample 0.1% EB - 1,200:1
VT - -80°C to 120°C

 

Room temp. 5mm BB probe of Z-Gradient:

1H S/N of sample 0.1% EB - 480:1
13C S/N- 330:1
15N S/N- 35:1
13P S/N- 180:1
19F S/N- 480:1
VT - -80°C to 120°C

6002 spectrometer

Agilent/Varian 600 MHz Spectrometer

Description:

It has two probes of 1H sensitivity 6,500:1. It is proper to collect data for NMR study of proteins, nucleic acids, and small molecules for high sensitivity.

 

Cold HCN probe of Z-Gradient (13C enhanced):

1H S/N of sample 2mM Sucrose - 650:1
1H S/N of sample 0.1% EB - 6,500:1
13C S/N of sample ASTM - 630:1
VT - 0°C to 80°C

 

Room temp. 5mm HCN probe of Z-Gradient:

1H S/N of sample 0.1% EB - 1,200:1
VT - -80°C to 120°C

 

6001 spectrometer

Agilent/Varian 700 MHz Spectrometer

Description:

It has six probes to collect data for study of solid state .

 

3.2mm Varian HXY BioMAS: 1H/31P-13C/13C-15N

 

4.0mm Varian HXY T3 MAS: 1H/31P-13C/13C-15N

 

Varian HX BioStatic rectangular coil: 1H/31P-15N for glass plates (300uL)

 

Varian HXY BiCell round coil: 1H/31P-13C/13C-15N for bicelles (150uL)

 

MagLab (Tallahasse,FL) HN rectangular coil: 1H/15N for glass plate samples (300uL)

 

MagLab HX round coil: 1H/15N or 1H/13C for bicelles (150uL)

700SS spectrometer

Agilent/Varian 600 MHz Spectrometer


Description:

It has two probes to collect data for solid state study.

 

3.2mm Varian HXY BioMas:

1H/31P-13C/13C-15N

 

Varian HX BioStatic rectangular coil:

1H/31P-15N for glass plates (300uL)

600SS spectrometer

Go to Top